EchoTouch庐 US06 & US12 Reflective Ultrasonic Liquid Level Transmitter
APPLICATION
The intrinsically safe reflective ultrasonic level transmitter provides continuous level measurement up to 39.3鈥 (12m) with a 4-20 mA analog and HART digital signal output, and is configured via its integral push button display module or WebCal software. The non-contact liquid level sensor features our proprietary Reflective Technology鈩 that delivers reliable level measurement in condensing environments. Select this sensor for bulk tanks with non-foaming or highly vaporous media such as chemicals, water, wastewater and oil. Typical applications include bulk storage, neutralization tank, clarifier and waste sumps.
FEATURES
Offered in 6m (19.6鈥) and 12m (39.3鈥) measurement ranges
Reflective Technology鈩 measures reliably with condensation
Corrosion resistant PVDF transducer with aluminum enclosure
Narrow 3鈥 (7.6cm) beam width for applications with limited space
LCD display indicates level in inches, meters or percent of span
HART communication in point to point and multi-drop modes
Fail-safe diagnostics with selectable fail-safe signal outputs
Configuration via push button display or WebCal software
Automatic temperature compensation from -40潞 to 80潞 C.
REFLECTIVE
Condensation is the most common variable in liquid level applications. Condensation attenuates the acoustic signal of ultrasonic sensors with horizontal transducers, weakening their signal strength and signal to noise ratio by up to 50%, and substantially reducing their measurement reliability. At the core of Reflective Technology鈩 is a simple fact. Unlike flat horizontal surfaces, significant water droplets cannot adhere to smooth vertical surfaces. By orienting the transducer vertically, condensation runs off the transducer and does not affect sensor performance. The unimpeded transmit and receive signals are redirected to and from the liquid off a 45潞 reflector, delivering reliable level measurement. Thanks gravity.
Reflective Transducer
Reliable Measurement
Horizontal Transducer
Signal Attenuation
P/N | DESCRIPTION |
---|---|
US06-0003-00 | 6m (19.6鈥) range, 2鈥 NPT, w/o Fob |
US06-0003-01 | 6m (19.6鈥) range, 2鈥 NPT, w/Fob |
US06-0013-00 | 6m (19.6鈥) range, 2鈥 G, w/o Fob |
US06-0013-01 | 6m (19.6鈥) range, 2鈥 G, w/Fob |
US12-0003-00 | 12m (39.3鈥) range, 3鈥 NPT, w/o Fob | July 2019 |
US12-0003-01 | 12m (39.3鈥) range, 3鈥 NPT, w/Fob | July 2019 |
US12-0013-00 | 12m (39.3鈥) range, 3鈥 G, w/o Fob | July 2019 |
US12-0013-01 | 12m (39.3鈥) range, 3鈥 G, w/Fob | July 2019 |
LB12-1001 | Intrinsic safety barrier |